BAL SX302 ETH EN 3.1 Operating instructions Series SX302 Alphanumeric large size displays with Ethernet interface
10 BAL SX302 ETH EN 3.1 Status indicators The status indicators (LEDs) of the central processing unit have the following function: READY STAT: On
BAL SX302 ETH EN 3.1 11 Socket connection The units are set up as TCP server by default. The data is transmitted to port 8000 via a socket connecti
12 BAL SX302 ETH EN 3.1 Brightness The brightness of the display can be reduced with the following command: Normal brightness: $L0 Reduced brightnes
BAL SX302 ETH EN 3.1 13 Chapter 4 Parameterization Menu The parameterization of the devices is carried out in a menu of the menu display. Durin
14 BAL SX302 ETH EN 3.1 Menu item Settings Menu display IP IP-Address Static P Stat DHCP* P DHCP I1 IP-Address 0 Byte 1 (
BAL SX302 ETH EN 3.1 15 Menu item Settings Menu display R Switching output No wiping pulse* r OFF Wiping pulse 1 sec r Wip
16 BAL SX302 ETH EN 3.1 Chapter 5 Configuration MAC address The MAC address of the unit is to be found on the Ethernet coupling of the control p
BAL SX302 ETH EN 3.1 17 Chapter 6 Technical data Unit properties The model designation is structured as follows: SX302 – / / – /
18 BAL SX302 ETH EN 3.1 Max. power consumption Units with one-side display Units with double-sided display 1 digit 1 digit SX302-01/10/0
BAL SX302 ETH EN 3.1 19 Chapter 7 Unit measurements and weights Units with one-side display The following figure shows unit version S302-04/10/4
2 BAL SX302 ETH EN 3.1 MAC address: : : : : : Site of the unit: Germany France Sieber
20 BAL SX302 ETH EN 3.1 Units with double-sided display The following figure shows unit version S302-04/10/4x-2xx/xx-xx, representing the other unit
BAL SX302 ETH EN 3.1 3 Table of contents Chapter 1 Safety precautions Important information Safety Intended use Mounting and installation Ground
4 BAL SX302 ETH EN 3.1 Chapter 6 Technical data Unit properties Max. Power consumption Switching output Screw clips Housing colors Front frame Ambi
BAL SX302 ETH EN 3.1 5 Chapter 1 Safety precautions Important information Read these operating instructions before starting the unit. They prov
6 BAL SX302 ETH EN 3.1 Grounding All devices are equipped with a metal housing. They comply with safety class I and require a protective earth conne
BAL SX302 ETH EN 3.1 7 Chapter 2 Unit description Model designation The model designation of the units is: SX302-xx/xx/xx-xxx/xx-E0 x = The &a
8 BAL SX302 ETH EN 3.1 Power supply unitLNPEPower supplyCentral Processing UnitRJ45Ethernet-InterfaceEthernet-connectionCOSwitching outputNC NO10M100
BAL SX302 ETH EN 3.1 9 Parameterization The parameterization of the unit is done by means of a menu in the menu display (see chapter 4). Ethernet