Moxa Technologies NPort IA5150 series Manual do Utilizador Página 36

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 108
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 35
NPort IA5150/5250 Series User’s Manual Web Console Configuration
5-11
Baud rate
Setting Factory Default Necessity
110 bps to 230400 bps 115200 bps Required
Data bits
Setting Factory Default Necessity
5, 6, 7, 8 8 Required
When the user sets Data bits to 5 bits, the Stop bits setting will automatically change to 1.5 bits.
Stop bits
Setting Factory Default Necessity
1, 2 1 Required
Stop bits will be set to 1.5 when Data bits is set to 5 bits.
Parity
Setting Factory Default Necessity
None, Even, Odd, Space, Mark None Required
Flow control
Setting Factory Default Necessity
None, RTS/CTS, DTR/DSR, Xon/Xoff RTS/CTS Required
FIFO
Setting Factory Default Necessity
Enable, Disable Enable Required
NPort IA5150/5250’s serial ports provide a 16-byte FIFO both in the Tx and Rx directions. To
prevent data loss during communication, disable the FIFO setting when your serial device does not
have a FIFO.
Interface
Setting Factory Default Necessity
RS-232
RS-422
2-wire RS-485
4-wire RS-485
RS-232 Required
Operating Settings
Click on Operating Settings, located under Main Menu, to display the operating settings for both
of NPort IA5150/5250’s serial ports.
Vista de página 35
1 2 ... 31 32 33 34 35 36 37 38 39 40 41 ... 107 108

Comentários a estes Manuais

Sem comentários