Moxa-technologies Moxa Smartio C168H Manual do Utilizador Página 17

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 16
Hardware Installation
Smartio C168H/PCI Users Manual 2-5
RS-422/485 Port Switch of Opt8J
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
DIP
ONDIP
RS-422 Mode
Set the respective switch to OFF position to use RS-422 interface. This means the
port is always ready to transmit and receive data simultaneously (full-duplex).
RS-485 Mode
The Opt8J supports only 2-wire RS-485 communication. Set the respective switch
to ON position to use RS-485 interface. This means the port can transmit data only
when RTS is asserted, and receive data only when RTS is not asserted (half-duplex).
Refer to Chapter Connection Option (Opt8x) and Cable Wiring for RS-
422/RS-485 cable wiring, and also to Chapter Serial Programming Tools for
Opt8J RS-485 programming details.