Appearance
NPort IA5150: 1-port RS-232/422/485 serial device server, 2 x 10/100BaseT(X) (RJ45, single IP)
NPort IA5150-T: NPort IA5150, -40 to 75°C operating temperature
NPort IA5150I: 1-port RS-232/422/485 serial device server with 2 KV isolation, 2 x 10/100BaseT(X) (RJ45, single IP)
NPort IA5150I-T: NPort IA5150I, -40 to 75°C operating temperature
NPort IA5150-M-SC: 1-port RS-232/422/485 serial device server, 2 x 10/100BaseF(X), multi mode fiber (SC connector)
NPort IA5150-M-SC-T: NPort IA5150-M-SC, -40 to 75°C operation temperature
NPort IA5150I-M-SC: NPort IA5150-M-SC with 2 KV isolation
NPort IA5150I-M-SC-T: NPort IA5150-M-SC with 2 KV isolation, -40 to 75°C operation temperature
NPort IA5150-S-SC: 1-port RS-232/422/485 serial device server, 2 x 10/100BaseF(X), single mode fiber (SC connector)
NPort IA5150-S-SC-T: NPort IA5150-S-SC, -40 to 75°C operation temperature
NPort IA5150I-S-SC: NPort IA5150-S-SC with 2 KV isolation
NPort IA5150I-S-SC-T: NPort IA5150-S-SC with 2 KV isolation, -40 to 75°C operation temperature
NPort IA5250: 2-port RS-232/422/485 serial device server, 2 x 10/100BaseT(X) (RJ45, Single IP)
NPort IA5250-T: NPort IA5250, -40 to 75°C operation temperature
Package Checklist
Optional Accessories
• 1 NPort IA Serial Device Server DIN Rail Power Supply: See page 12-7
• Quick Installation Guide
Optical Fiber Patch Cord: See page 12-10
• NPort Document and Software CD-ROM
Terminal Block: See page 12-5
Power Jack to TB Power Cable
: See page 12-5
Ordering Information
Copper
Ethernet
LED
Indicators
Fiber optic
Ethernet
Reset
Dual Power Input and
Relay Output
RS-232
RS-232/422/485
RS-422/485
NPort IA5000 series device servers have two power inputs that can
be connected simultaneously to live DC power sources. If one power
source fails, the other source takes over automatically. Redundant
power inputs help assure non-stop operation of your device server.
Redundant Power Inputs
The built-in relay output can be used to alert administrators of
problems with the Ethernet links or power inputs, with the web console
indicating which Ethernet link or power input has failed. An e-mail
warning can also be issued when an exception is detected. These
functions are valuable tools that enable maintenance engineers to react
promptly to emergency situations.
Warning by Relay Output and E-mail